Great Good quality X-Ray Radiography Machine X-Ray Flaw Machine MSLMX17
Item Description
Great Good quality X-Ray Radiography Equipment X-Ray Flaw Device MSLMX17cellular x ray device digital dr system for medical center
THA MECHANICAL Component
The mechanical elements of this sequence equipment consist of the adhering to significant factors: the base device, pillar elements (like Upright Publish pieces, Rocker Arm parts, Locking items), tube components, and so on.
1. Base unit
The instrument adopts Orientation foot brake, one of most innovative constructions, which is stable and it is not simple to break. Throughout its usages, the machine can be mounted rapidly with the brake construction, stopping the device from moving ahead and backward. It is hassle-free to consider radiography in a stable and accurate scenario. Observe: If some faults happen, remember to adhere to as bellow:
one) It brakes successfully throughout the movement, but when end users launch the foot brake, the instrument are not able to shift usually. At this second, you should shift the device forward and backward slowly and brakes will be able to return to its unique situation, then you can thrust the machine easily.
2) After launch the foot brake and move forward as the phase one), if the machine nonetheless can not transfer, please use some gentle item to defeat the brake block beneath the foundation device until it can operate effectively. Normally it is the reason that it works for a prolonged time, and the foundation of the brakes lacks lubricant. Make sure you transfer the arm to the cheapest situation and lock right up until listening to a “crack” locking sound, and then gently go up a tiny and cease when meet up with resistance, then transfer the device to another aspect. The users can see the brake technique under the base unit and include oli, to make it slide freely. Soon after that, it will operate effectively.
three) In the course of the movement the equipment in the collision process, the caster is destroyed. You should tilt the machine as the previously mentioned two approaches, elevate the ruined aspect of the wheel, and remove it. Then fix or replace it.
2. Pillar areas
This machine is used to a merged pillar and rocker arm. It can just take films in every situation the tube elements cease, by making use of the constructed-in pressure spring and rocker arm to realize the up and down motion of tube elements. Observe: If some faults take place, remember to adhere to as bellow:
one) Tube factors can not end at a particular place as the person want.
It is brought on by the lengthy time use of pressure spring. Make sure you tilt the device in accordance to the “base unit” in Stage 2, then use the wrench to change the extension spring bolt of the base device, rotate clockwise to improve the tension, till it reaches a JCPT place.
two) Locking items can’t function.
Check no matter whether the head pins of the two sides on chrome-plated handles is broken or not. If indeed, you should adjust the tension spring in accordance to earlier mentioned NO.1), counter-clockwise rotate until finally the pressure spring impact can not find the money for to pull up, and get rid of the tube areas , then take away the locking items to verify the cushion of both sides free or not. Enjoyment restore the cushion, then set up locking parts into the arm pieces together, then put in the tube areas, at final modify the pressure spring bolt right up until JCPT.
three. Tube parts
Tube elements is composed of beam collimator, rotating handle, include and tube items. If some faults occur throughout use, such as not lighting of beam collimator lamp and so on., please mend and maintain in accordance to the corresponding sections of the guide if there is something mistaken with the tube pieces, remember to contact our business.
Solution Parameters
Main Technical Parameters:
Specs |
Power Output: 5.0KW Frequency : 50KHz X-ray Tube : Fixed anode Focus : 1.five Tube Voltage : forty~120KV (interval 1KV) Tube Current : 40~49KV 100mA 1~180 mAs 50~59KV 77mA 1~140 mAs 60~69KV 64mA 1~125 mAs 70~79KV 55mA 1~110 mAs 80~89KV 49mA 1~100 mAs 90~99KV 44mA 1~80 mAs 100~109KV 32mA 1~63 mAs 110~120KV 25mA 1~50 mAs mAs : 1.~180 mAs (46 steps) Power Supply: 220V±10% 50Hz inner-resistance≤1.0Ω Operation Method: Wire/Wireless control , 20 meters microwave distant management exposure. (Advantage) . It is different from infrared distant handle publicity, does not suffer any obstructions in the way |
Packing Details : 1220mm×900mm×1460mm , 1.7CBM
N.W. 142kgs G.W.212kgs
Parameters :
Standard-function, cellular X-ray system, committed for radiography of standing, seated or recumbent sufferers as nicely as for individuals in bed or on the working desk and as a standby emergency unit. High-frequency X-ray generator with the subsequent output:
one. Generator output: 5. kW
2. kV assortment: 40 kV – a hundred and twenty kV in 1kv steps
3. mA selection: 25~100 mA
four. Publicity time: four films per min, significantly less than twenty ms for every movie
five. X-ray tube:
Stationary anode tube with a focal place of 1.5*one.5 mm
six. Collimator:
vibrant field mild beam collimator with one hundred twenty W halogen lamp and auto shut-off facility.
7.Energy requirements :One section 220 V +/- ten% Voltage tolerance fifty Hz electrical power offer
eight.Cell stand: JCPT-bodyweight, reduced height cell and simply maneuverable stand.
9.The mobile radiographic unit also contain a handheld control and a microwave wireless distant manage for the 20-meter microwave remote Without having the restriction of Boundaries and directional ,various from the infrared distant manage . Grids reduce the fog line filters and elevate the degree of scattering distinction.
10.The device is offered with a line (electricity) cord of appropriate longevity, top quality, size and is secured with satisfactory strain reliefs
The unit contain, energy plugs that are adequate for the maximum voltage and present of the unit.
eleven. The optimum length from the floor: ≥ 17500mm, and bare minimum length from the floor :≤500mm, rotating about the horizontal axis a hundred and eighty °, rotation all around the vertical: ± 90 °, The collimator can rotate one hundred eighty °
Standard Configuration:
one ,Modular large-frequency and substantial-voltage X-ray generator Substantial-frequency inverter electricity.(five.0KW, 120KV, 100mA, 40KHZ) one set
2,Modern mobile X-ray photography Principal frame one set
3,Cell X-ray photography management method one established
four,Symmetric Adjustable beam limiter with mild one set
five,Remote controller ( Hand keep controller and Wireless Microwave control ,the distance is 20 meters ) one set
six,Basic spare areas Several
Utilization:
This is a modular X-ray photography health-related prognosis products, which is offered for wards,emergency,running area,ICU and so on. An cell analysis tools for photography of human body locutions this sort of as head,arms,thoracic cavity and waist stomach.
Features:
Lovely appearance, and effortless to go and run Have all the attributes of all the mobile X-ray images equipment.
Rocker arm use the patent technological innovation of single-arm help and self-JCPTd. This engineering can make the appearance and procedure significantly much more beautiful and convenient.
Apply the style of enlargement gate layout, the device will automatically locked when hand-off which can make the motion significantly safer.
Apply the patent technologies of automobile-trim patent among arm rotation and battery box. The machine can immediately change the barycentre in accordance to the rotation angle of the arm. All this make the sequence the lightest and smallest and simple for movement amid like merchandise.
We include the most current compact substantial-frequency and substantial-voltage X-ray generator, which ensure outstanding image top quality, while the skin dose is reduced , to shield the patient far better.
Adopt the technological innovation of kV and mAs numeral closed loop manage, Real-time handle of the microprocessor, which make sure the precision and repeatability of the output dose.
The parameter can be modify by the KV and mAs two-button method. High- brightness,blue screen Lcd show. With several stability shield perform these kinds of as above-voltage, in excess of-recent.
With 50 preset publicity applications, and can be modified and stored by the consumer for handy procedure.
With a large-good quality knockdown X-ray generator to minimize irradiation, which is considerably safer to setting and operator.
Has a established of failure cascading failure function. Exhibit the failure code. The program will routinely reset when the power is off which make sure the information risk-free.
With a symmetrical beam applicator to change the X-ray field and a collimator lamp to track down the submitted to ensure accurate radiograph.
With high frequency inverter to emit higher good quality X-ray and minimal dose on skin, and make certain outstanding definition and contrast of photographs.
The arms can rotate ±90°left and appropriate. It is handy to poisoning.
Undertake guide handle and distant handle techniques to handle the images purpose
Comprehensive Photos
Organization Profile