Percutaneous Kyphoplasty Instruments to Treat Vertebral Compress Fractures  Resulted From Osteoporosis, Vertebral Benign and Malignant Tumors

1. Basic Description
Vertebral Forming Unitized Surgical Devices Product 202 (PKP technique)are composed of
Puncture Needle, Xihu (West Lake) Dis. Pin, Dilating Tube, Doing work Cannula, Sound Bone Drill, Hollow Bone
Pushing Rod, Cement JCPT Gadget, Balloon and Inflation System. There are two sorts of
Puncture Needle, Locking-deal with and Rotary manage. The merchandise are sterilized with ethyleneoxide. And the valid interval of sterilization is 24 months. One use.

two. Contraindication
      

  1. Osteomyelitis
  2. A notable bone block to the rear vertebral human body
  3. Tumor lumps in the rear facet, which might include the vertebral canal
  4. Extreme cardiopulmonary dysfunction, coagulation ailments, sepsis and the other diseases that is not appropriate for the operation

three. Structure of devices

    Devices Composition Specification(mm)
    Puncture Needle with Locking Manage

    one,Inner Stylet  2,Outer Sleeve  3,Outer Sleeve Handle 
    four,Stylet Handle  five,Locking Button

    Diameter three.,three.2,four.
    Size 100,126,one hundred thirty
    Puncture Needle with Rotary Take care of

    one,Inner Stylet    two,Outer Sleeve   3,Outer Sleeve Handle 
    four,Stylet Deal with

    Diameter three.,four.
    Length a hundred,126
    Xihu (West Lake) Dis. Pin   Diameter one.2,one.five
    Length 300
    Dilating tube

    1,Dilating tube   two,Deal with

    Diameter three.four,3.six
    Length 140
    Operating Cannula

    1,working cannula  2,operating cannula deal with

    Diameter 4.,four.two
    Duration 123
    Solid Drill

     

    Diameter three.,3.four,3.six
    Duration a hundred ninety
    Hollow Drill   Diameter three.,three.4,three.6
    Size one hundred ninety
    Pushing Rod   Diameter two.
    Duration 220
    Cement
    Injector
      Diameter three.,3.4
    Size 195
    Balloon

     

    1. Balloon   two,Ring Mark  3,Hook up Tube 

    four,Balloon Seat      5,Stylet Seat   six,Stylet

    Diameter 14
    Duration 17
    Inflation
    System

    one,Tee 2,Higher Force Tube three,Force Gauge 4,Lock Nut Handle 5,Plunger Deal with

    Potential 20ml
    Strain 30atm

    four. Organization Cultural Improvement
        

    Many thanks for checking out us!