Surgical Stapler Disposable Linear Cutter Stapler

Surgical Stapler Disposable Linear Cutter Stapler

Disposable Linear Cutter Stapler
I. Item Description 
The disposable linear cutter is applicable for transection, resection, and the generation of anastomoses. It has 4 rows of staples with a knife among the next and 3rd row. It is a sterile, single-individual-use instrument that simultaneously staples and divides tissue
The YQG sequence linear cutter is a single-individual-use system. It provides 4 staggered rows of titanium staples, with a knife between the second and third row. It can be operated by 1 hand. Two-way push knob can be appropriate for remaining or right hand.
We have two kind of staple top cartridges which supply the versatility to produce suitable compression for the targeted tissue.
 
II. Scope of Software
It is applicable to mutilation, excision and suture in the operation of alimentary canal this sort of as tummy and intestines.

III. Exterior Structure 
    
IV. Contraindication 
1. Severe mucous edema.
two. By no means use the stapler with staple top of four.5mm for any tissue whose compressed thickness is less than 2.0mm, because the stapler staple cannot fully tighten up to quit bleeding in this situation.
3. Never use the stapler with staple height of 4.5mm for any tissue which fails to be compressed simply to be 2.0mm thick, since the tissue thickness is beyond the suturing specification in this scenario.
4. By no means use the stapler with staple peak of three.85mm for any tissue whose compressed thickness is considerably less than one.5mm, due to the fact the stapler staple are not able to entirely tighten up to end bleeding in this scenario.
5. Never use the stapler with staple top of three.85mm for any tissue which fails to be compressed effortlessly to be one.5mm thick, simply because the tissue thickness is over and above the suturing specification in this scenario.
six. In no way use the instrument for any tissue whose compressed thickness is much less than 1mm, due to the fact the stapler staple can’t completely tighten up to end bleeding in this situation.
seven. The instrument shall not be used for livers or spleens, because closing the instrument may cause destructive impact due to their compression attributes.

V. Recommendations for Operation
one. Just take the instrument out of the package in the sterile purifying region. To stay away from any injury, the instrument shall be dealt with gently.
2. Open up the totally free handle include, independent the cutter assembly from the anvil, and then remove the cartridge go over.
3. Clamp the tissue to be lower and sutured in between the cartridge and the anvil help, and then push the cost-free handle cover to the locking placement (Note: The totally free manage go over should be pressed to its place).
4. Maintain the cutter stapler in one hand and push the ejector pad with the thumb and forefinger of the other hand to the firing place (as the chopping knife nevertheless does not start off chopping, the hand come to feel is mild), and then proceed pushing the ejector pad uniformly forwards to the front finish (the hand really feel is hefty, indicating that the chopping knife commences reducing the tissue and suturing the tissue at equally sides).
five. Reset the ejector pad (there is red indicator on the instrument, as shown in determine one). Pay out consideration that the stapler cannot be lifted quickly. The cost-free handle go over should be initial introduced and the cartridge and anvil help shall be divided after that, the instrument shall be taken off, and then the procedure is finished.
Removable assembly:
Utilization of removable assembly of disposable linear cutter stapler and cartridge
Be certain that the ejector pad returns to its unique place, and then pull the cost-free deal with protect open to get rid of the employed assembly and replace it with a new one particular set the new assembly in the assembly holder and repair it, and then take away the include the assembly can be used in the very same procedure in accordance to the utilization.

VI. Storage
The item shall be saved in a well-ventilated place in which no corrosive gases exist and relative humidity is not more than eighty%.
 
VII. Maker and Its Handle and Speak to Number

Design Cartridge Design Chopping Duration Staple Peak(mm) Shade of Cartridge Suture Length(mm) Suture Thickness(mm)
YQG-55L YQGZ-55L 55 three.85 Blue sixty one.five
YQG-55H YQGZ-55H 55 four.fifty Green sixty 2.
YQG-75L YQGZ-75L 75 three.eighty five Blue eighty one.five
YQG-75H YQGZ-75H 75 four.50 Environmentally friendly 80 2.
YQG-100L YQGZ-100L one hundred three.85 Blue 105 one.5
YQG-100H YQGZ-100H one hundred 4.fifty Eco-friendly one zero five 2.

Company: HangJCPT JCPT JCPT Deveices
Address: No. 2188 Xihu (West Lake) Dis. Rd, Xihu (West Lake) Dis. District, HangJCPT Town China
 
 
Zip Code: 213012
World wide web:

Surgical Stapler Disposable Linear Cutter Stapler

Tags:

locking collar

As one of leading locking collar manufacturers, suppliers and exporters of products, We offer locking collar and many other products.

Please contact us for details.

Mail:[email protected]

Manufacturer supplier exporter of locking collar

Recent Posts