STHangJCPTRD COMPOSITION:

 Microcontroller control open up kind radiant warmer with manual and servo technique

 Display pores and skin established facility, skin observed temperature in ºC and warmth power independently

 User friendly delicate contact panel massive and vibrant LED Screen

 Ceramic infrared heating aspect for successful warming

 Audible and visual alarm facility for overheating over and above established temperature range,

   probe failure,   power failure, program failure and heater failure

 Warmer will be feeling the skin probe failure and reduce off the heater

 Warmer head will rotate and swivel in diverse direction

 Inbuilt battery back again- up in the course of power failure

 Keyboard locking facility to avoid undesired consumer modification of the established parameter.

 Height of the warmer will adjustable

 Control panel will liquid proof and allow easy and hygienic disinfection

 JCPT alarms for patient basic safety

 Large mattress, drop down aspect panels for simple accessibility to new-born

 Examination lamps for easy observation of new-born

 

JCPT Requirements:    

 Observation JCPT :   1000 Lux

 Color Temperature assortment : 3700k to 5100k

 Patient management ( baby manner )   : 34°C   to 37.5°C in increments .1°C ( 95°F to ninety nine.5°F )

 Manual mode alter heater output : 10 – a hundred% with 5% increment, auditory and visual alarm will give each and every 15 min.

 Temperature measurement accuracy:   ± .3°C, resolution: ± .1°C, probe accuracy: ± .1°C

 Warmer have with bassinet trolley. Mattress foam density   25kg/cm³, transparent collapsible     side wall, easy detachable for cleaning, mattress size : 20″ x 28 “

 Size of fall down   5″ (±1″ ) mattress surface area, 6mm thick, obvious and transparent.     

 Bed   peak about   eighty ~ 100cm from the flooring and eighty ~ 90cm from the warmth source.

 The infant bed is crevice totally free for simplicity of cleaning, infection management and mattress employed to be

   biocompatible material.

 Heater Component : 600 watts

 Heater will minimize off , if the optimum irradiance at any stage of the mattress location exceeds a total irradiance amount of 10mw/cm² or over 60% of the heater output ( amongst 10 to thirty min)

 Bed tilt mechanism : -10-15°  

 Skin temperature probe measurement : ≤ 10mm dia   three~ 4mm thick ( biocompatible), pliable probe wire and non-stiff   

 Castor wheels 2 are lockable

 Ambient temperature : ten-40°C

 Relative Humidity :   15 – 90%

 Power supply : 220-240VAC, 50Hz

 

Components:

one.Mattress-one No.

2.IV pole-one No.

3.Skin Probe-1 No.

four.X-ray cassette tray-one No

5.Operational and support manual – one set every single

 