Good Good quality X-Ray Cellular Device Rapiscan X-Ray Device MSLHX04
Solution Description
Great Good quality X-Ray Mobile Device Rapiscan X-Ray Device MSLHX04mobile x ray equipment digital dr method for clinic
The large frequency large-voltage x-ray generator for health care prognosis belongs to variety I of health-related instrument equipment, which is broadly utilized in productive institution for generating large frequency x-ray machine for medical analysis as the supporting of large frequency x-ray machine core components for healthcare analysis and improve the technological innovation of the high frequency x-ray equipment for healthcare prognosis. The maximumpower output is 50kW, the changing range of radiography tube present is 10mA ~ 630mA, the altering selection of radiography tube voltage is forty kV ~ a hundred and fifty kV, the assortment of current-time merchandise is .5mAs ~ 630mAs, and operating frequency ≥ a hundred kHz.
The solution has the adhering to prominent functions:
Simulation and digital double loop accuracy manage approach:
With high frequency inverter circuit and microprocessor, simulation make up of the special chip PWM, digital double
loop comments handle technique, to obtain high accuracy high voltage output, even if power fluctuation, still can output stable x-rays
Substantial precision radiography time handle:
The shortest exposure time is .002 seconds, can make radiography fast at any time and entirely free of charge the impact of energy phase, and generate higher good quality x-ray images simply and reduce patients struggling x-ray radiation at the exact same time.
Higher precision tube recent control:
x-ray tube recent is adopted two grades large frequency converter, sampling tube existing of higher speed A/D converter through microprocessor calculation for the true-time manage, microprocessor manage the permitting load of x-ray tube, x-ray tube effectively capable radiography problems can be established.
Varieties of placing modes for radiography situations:
Pick kV, mA and mAs respectively for radiography circumstances set, the rapid anatomy programming radiography (APR) for human body is simplified for the procedure In accordance to x-ray tube potential restrict locking a few parameters decide on and make capacity defense
Default self-protection, self-analysis:
Once show up malfunction, generator chain security, alarm gadget, inquiring fault code, practical for servicing treatment method
Small dimensions, light fat, lowering installation area.
Product Parameters
Operating condition:
Environmental temperature: +10ºC ~ +40ºC
Relative humidity: 30% ~ seventy five%
Atmospheric stress: 70kpa ~ 106kpa
Transportation and storage issue:
Environmental temperature: -20ºC~+70ºC
Relative humidity: ten% ~ a hundred% (such as condensing)
Atmospheric strain: 50Kpa ~ 106Kpa
Electricity prerequisite:
Electricity voltage: AC380V ± 38 V
Stage amount: Three period 5 wires
Power frequency: 60Hz±1Hz
Electrical power internal resistance: considerably less than .5 Ω
Doing work system: Intermittent load and steady operate
Input power: ≤ 80kVA
Optimum output electrical power:
P= 100kV×500mA = 50kW
Nominal energy:
100kV, 500mA, .1s, 50kW
Modifying variety of tube voltage and recent:
Radiography tube voltage: 40 kV ~ one hundred fifty kV
Radiography tube present: 10mA ~ 630mA
The deviation of x-ray tube voltage: ±10%
The deviation of x-ray tube present: ±20%
Recognize: Existing and present-time solution arrange are according to R’ 10 quantity technique.
Functions Console:
Microprocessor controlled Digital display, Liquid crystal display contact display screen
Line voltage adjustment one hundred eighty-260V
Overload defense technique
Emergency change
Circuit breaker major change
High voltage generator (which includes computer console):
50KW/150kVp energy storage kind substantial frequency
Enter electrical power: 380V, 60Hz ± 1Hz.
Electricity inside resistance: < 0.5Ω
Output electrical power: 50kW output voltage: forty ~ 150kV output current: 10~630mA
nominal frequency ≥ 100kHz large voltage generator
Time variety: .0571-6.3s
X-ray Tube:
Dual Concentrate:
modest .6mm/1.2mm,
With 300KHU Heat Unit capacity for rotating anode
150kVp, High/regular speed rotor
X-ray Tube:
Dual Target: little .6mm/ large1.2mm,
With 300KHU Heat Device capability for rotating anode
Desk:
Stationary
Radiographic Enclosed Design Table
Wall mounted
Bucky Grid, Ratio: 12:1
Overall filtration 2.5mm Al equal
Inherent filtration one.5mm Al equivalent
Equipment:
1pc movie viewer, four banking companies, 14″x17″ each bank
1set x-ray film markers composed of English figures and alphabets
2pcs guide apron with .25mm direct equivalence
2pcs thyroid protect, .25mm guide
4pcs fourteen”x17″ Green sensitive cassettes
4pcs 11″x14″ Eco-friendly sensitive cassettes
4pcs eight”x10″ Environmentally friendly sensitive cassettes
Anode cooling chart
Tube ranking chart
Thorough Photos
Firm Profile